Gas Fired or Electrically Heated
The horizontal quench furnace is a cost- effective alternative to our drop bottom furnaces and is available in ten (10) standard sizes. The equipment utilizes an electrically operated pusher/extractor mechanism that provides a quench time of 10-15 seconds, which combined with the load capacity of up to 6,000 lbs makes it ideal for a wide range of applications.
A high capacity recirculation blower, along with fully enclosed & pressurized supply ducts, delivers heated air with a combination airflow arrangement. This type of uniform airflow ensures even heat distribution throughout the work chamber and excellent temperature uniformity.
All units are fully factory tested, adjusted and certified by a 154 point quality inspection PRIOR to shipment, which results in lower installation and start-up costs. Optional PLC control, data acquisition, trending, and reporting are also available.
Application:
The horizontal quench furnace is used for heat treating. It can be used for loads up to 6,000 lbs and has a quench time of 10-15 seconds. The horizontal quench furnace has maximum temperature ratings up to 1,400° F and provides excellent temperature uniformity.
Benefits:
Cost effective alternative to a drop bottom furnace
High load capacity ideal for a wide range of applications
Automated controls available for easier operation
Fully factory assembled and tested prior to shipment to reduce installation and start-up time
"Shown with optional pitted tank"
*Custom Sizes Available*
Please contact us at 262-642-3938 or sales@wisoven.com to
discuss your specific application and design requirements.
Standard Features:
High capacity recirculation blower
Quench tank water agitation pump with distribution manifold
Gas fired or electrically heated
Combination airflow through oven chamber
Carbon steel work grid (stainless steel also available)
Standard temperature uniformity of +/- 15° F, tighter tolerances available upon request
Air operated vertical lift oven door and quench platform
Main power disconnect switch
480/3/60 power supply (other voltages available)
FM, NFPA, NEC compliant
Shipped completely piped, wired, fully tested and certified (as required)
Larger capacity tanks for reduced quench temperature rises
Quench tank cooling
Stainless steel tank construction for corrosion resistance
Automated operation
Installation, start-up and training at your facility (turnkey or a working supervisor)
Standard Operating Procedure:
Parts are loaded on a work grid located on the rollers (quench platform). An electric pusher/extractor mechanism pulls the load into the furnace for heat treating. After the heating cycle is completed, the pneumatically operated vertical lift door is manually opened and the extractor mechanism pushes the load onto the quench platform and then the load is quenched. Purchasing an optional 2 tier quench platform will allow one load to be charged into the furnace while another load is quenched.